  1. Why does this presumably 15A GFCI say its a 20A receptacle?

    Aug 14, 2024 · A UL requirement is that all 15A faced receptacles (i.e. NEMA 5-15 sockets) must have 20A passthru. The companion rule to this is NEC 210.21 (B) (3) which allows 15A …

  2. Why is it safe to use 15 A receptacles on a 20 A circuit?

    A 15A outlet is rated for 15A, with a 20A pass through. That is to say that the 20A circuit is in continuance throughout the circuit, however the receptacle itself (the contacts) are rated for …

  3. Would there be a problem installing 20A switches on a 15A circuit?

    There is no problem with using a 20A switch on a 15A circuit, as the breaker will trip and protect the switch from over-current. Using a 15A switch on a 20A circuit is potentially dangerous …

  4. electrical - Why does US Code not allow a 15A single receptacle …

    Dec 6, 2020 · What am I missing about why a 15A single receptacle cannot be the only connection to a 20A circuit? (This answer quotes more of Code 210.21, and goes into more …

  5. appliances - Home Improvement Stack Exchange

    I've searched the answer which seems to be 1800W (120V x 15a) but it's not clear to me whether the rating is for each of the two outlets or the pair together. So I would like to know: what is the …

  6. What is the purpose of a double pole breaker for separate 15A …

    4 My new house is done being built and I am going to come in and install my new gas range and dishwasher, both 120V 15A appliances. I got thoroughly confused looking at the breaker box …

  7. Is there a 30A receptacle which will accept "regular" 5-15 and 5-20 …

    Jul 14, 2021 · Nope, that was a "one-off" specifically for 15A receptacles. That is because UL requires 15A receptacles to be rated for 20A internally. They make no such requirements of …

  8. Can I use a commercial appliance in my home?

    Feb 27, 2025 · The described would be just a regular outlet and 15A is the lowest amp circuit typically found in US homes. However, the "dedicated" part is not very common for fridges. …

  9. Replacing old Nutone Despard/triple Switch with Triple Rocker

    Feb 17, 2023 · I'm looking to replace an old Nutone Despard/triple switch, which has individual controls for the light, vent & heat aspects of the overhead unit. Through a series of push …

  10. breaker size, wire gauge, and minimum circuit ampacity (MCA)

    Jun 6, 2024 · Which actually makes sense. For a pure resistive load, MCA == wattage/voltage. And while typically each water heater will be on its own circuit and therefore breaker size = …